Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8VS / Omron Power Supply S8VS Series S8VS-09024

Omron Power Supply S8VS Series S8VS-09024

Omron Power Supply S8VS Series S8VS-09024
share

Total Run Time Monitor , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , With Undervoltage Alarm (Ttransistor (Sourcing))
Power rating 90 W
Efficiency 83% TYP. ï¼ˆAt 100 VAC input)84% TYP. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 1.9 A TYP. ï¼ˆAt 100 VAC input)1.0 A TYP. ï¼ˆAt 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1.0 mA Max. (At 200 VAC input)
Inrush current 14 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))28 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)250 mV Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 3.75 A
Start up time 460 ms TYP. ï¼ˆ100 VAC input)300 ms TYP. ï¼ˆ200 VAC input)
Hold time 28 ms TYP. ï¼ˆ100 VAC input)132 ms TYP. ï¼ˆ200 VAC input)
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 115 to 150 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) EMI: EN61204-3 Class BEmission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 30 mA)Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs/alarm outputs and all inputs/PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight 490 g Max.

Omron Power Supply S8VS Series S8VS-06024A
Omron Power Supply S8VS Series S8VS-06024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 120 W , Output 24 V 5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 120 WEfficiency 83% 
Omron Power Supply S8VM Series S8VM-05024CD
Omron Power Supply S8VM Series S8VM-05024CD
Standard Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 24 V 2.2 APower rating 50 WEfficiency 80% Min.Rated in
Omron S8JX Switch Mode Power S8JX-G05005
Omron S8JX Switch Mode Power S8JX-G05005
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 5V 10A , Front-mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-input voltage
Omron Power Supply S82S S82S-7727
Omron Power Supply S82S S82S-7727
Input 12 to 24 VDC , 7.5 W , Output +-12 V 0.2 A/0.2 APower rating 7.5 WEfficiency 64% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to&
Omron Power Supply S8JX Switch Mode Power S8JX-P15012
Omron Power Supply S8JX Switch Mode Power S8JX-P15012
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 12V 13A , Front-mounting typePower rating 150 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input volt
Omron S8JX Switch Mode Power S8JX-G03512D
Omron S8JX Switch Mode Power S8JX-G03512D
Open-Frame Type , Input 100 to 240 VAC , 35W , Output 12V 3A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input voltage 1
Omron S8JX Switch Mode Power S8JX-P05024CD
Omron S8JX Switch Mode Power S8JX-P05024CD
Covered type , Input 100 to 240 VAC , 50W , Output 24V 2.1A , DIN Rail mounting typePower rating 50 WEfficiency 77% Min.Rated input voltage 100 to 240 VACAllowable-input&
Omron Power Supply S8TX Series S8TS-02505F
Omron Power Supply S8TX Series S8TS-02505F
Basic Block , Connector Terminal Type , Input 100 to 240 VAC , Output 5 V 5 APower rating 25 WEfficiency 73% TYP. ï¼ˆAt rated input, 100% load)Rated input voltage
Omron S8JX Switch Mode Power S8JX-G03515C
Omron S8JX Switch Mode Power S8JX-G03515C
Covered type , Input 100 to 240 VAC , 35 W , Output 15 V 2.4 A , Front-mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated input volta
Omron S8JX Switch Mode Power S8JX-P10005C
Omron S8JX Switch Mode Power S8JX-P10005C
Covered type , Input 100 to 240 VAC , 100W , Output 5V 20A , Front-mounting typePower rating 100 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&